Denial of Service Vulnerability in Siemens SCALANCE S613

5.3MEDIUM

Key Information:

Vendor

Siemens

CVE ID
CVE ID:
CVE-2016-3963
Vendor
CVE Published:
8 April 2016

Timeline

Exploit known the day it was published

  • ๐ŸŸก

    Public PoC available

  • ๐Ÿ‘พ

    Exploit known to exist

  • Vulnerability published

  • Vulnerability Reserved

Badges

๐Ÿ‘พ Exploit Exists๐ŸŸก Public PoC

How risky is it?

  • Yes: Works over the network, no login needed
  • Yes: Public exploit code (1 proof-of-concept)
  • No: Not on CISA's exploited list
  • No: No ransomware use seen

Our verdict

Patch this week

Exploitation is likely. Prioritise the fix.

What to do

1Check the vendor's fix

No fixed version is recorded yet. The vendor advisory is the authoritative source for patches.

Read the vendor advisory โ†—
2Can't patch yet? Reduce exposure

It can be reached over the network, so limit who can reach Scalance S613. Block it from the internet, allow only trusted hosts or a VPN, and turn off the affected feature if you don't use it, until you can update.

3Look for signs of compromise

Exploit code is public, so check logs on exposed Scalance S613 systems for unusual requests or new processes from before you patched. The 1 public proof-of-concept show what an attack looks like.

4Why it's rated "Patch this week"
  • Exploit code is public, so attacks are easy to copy.
  • It can be exploited remotely without credentials.
  • Its CVSS severity is medium (5.3).

What is CVE-2016-3963?

The Siemens SCALANCE S613 product is vulnerable to a Denial of Service (DoS) attack, allowing remote attackers to disrupt services by targeting TCP port 443. This could lead to web server outages, impacting operations reliant on consistent network availability. Organizations utilizing SCALANCE S613 should assess their network configurations and security measures to mitigate potential exploitations.

Exploit Proof of Concept (PoC)

PoC code is written by security researchers to demonstrate the vulnerability can be exploited. PoC code is also a key component for weaponization which could lead to ransomware.

References

Arbitrary Code Execution Vulnerability in Siemens Software Center

CVE-2026-110936
SiemensSiemens Software Center๐Ÿ‘พ8.4HIGH

Unauthorized Access in SIMATIC IoT2050 Devices

CVE-2026-58115
SiemensSimatic Iot2050 Advanc...๐Ÿ˜„๐Ÿ‘พ10CRITICAL

Femap Vulnerability: Out-of-Bounds Write in Catia MODEL File Parsing

CVE-2024-27907
SiemensSimcenter Femap7.8HIGH
View more Siemens vulnerabilities...

Facts on this page come from the sources listed above; the writeup is AI-assisted. How we rate vulnerabilities ยท Report a correction

EPSS Score

8% chance of being exploited in the next 30 days.

CVSS V3.1

Score:
5.3
Severity:
MEDIUM
Confidentiality:
None
Integrity:
None
Availability:
None
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged
.