Failure to release memory may exhaust system resources

CVE-2018-5739

6.5MEDIUM

Key Information

Vendor
Isc
Status
Kea Dhcp
Vendor
CVE Published:
16 January 2019

Summary

An extension to hooks capabilities which debuted in Kea 1.4.0 introduced a memory leak for operators who are using certain hooks library facilities. In order to support multiple requests simultaneously, Kea 1.4 added a callout handle store but unfortunately the initial implementation of this store does not properly free memory in every case. Hooks which make use of query4 or query6 parameters in their callouts can leak memory, resulting in the eventual exhaustion of available memory and subsequent failure of the server process. Affects Kea DHCP 1.4.0.

Affected Version(s)

Kea DHCP Kea DHCP 1.4.0

References

CVSS V3.1

Score:
6.5
Severity:
MEDIUM
Confidentiality:
None
Integrity:
None
Availability:
High
Attack Vector:
Adjacent Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged

Timeline

  • Vulnerability published

  • Vulnerability Reserved

Collectors

NVD DatabaseMitre Database
.