Local Command Injection Flaw in Siemens SIMATIC RTLS Locating Manager
Key Information:
- Vendor
Siemens
- CVE ID
- CVE ID:
- CVE-2020-10051
- Vendor
- CVE Published:
- 9 September 2020
Timeline
Vulnerability published
Vulnerability Reserved
How risky is it?
- No: Needs local access
- No: No public exploit yet
- No: Not on CISA's exploited list
- No: No ransomware use seen
Our verdict
Check today
Find out if you're affected. If you are, patch.
What to do
1Check the vendor's fix
No fixed version is recorded yet. The vendor advisory is the authoritative source for patches.
Read the vendor advisory β2Why it's rated "Check today"
- Its CVSS severity is high (7.8).
What is CVE-2020-10051?
A local command injection vulnerability has been identified in the Siemens SIMATIC RTLS Locating Manager. This issue arises due to multiple services running with SYSTEM privileges, and the absence of properly quoted call paths. As a result, a local attacker is able to inject arbitrary commands that can be executed in place of the legitimate service, potentially compromising the security of the system.
Affected Version(s)
SIMATIC RTLS Locating Manager All versions < V2.10.2
References
More Siemens Vulnerabilities
Arbitrary Code Execution Vulnerability in Siemens Software Center
Unauthorized Access in SIMATIC IoT2050 Devices
Femap Vulnerability: Out-of-Bounds Write in Catia MODEL File Parsing
Facts on this page come from the sources listed above; the writeup is AI-assisted. How we rate vulnerabilities Β· Report a correction