RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard
CVE-2020-10270

9.8CRITICAL

Key Information:

Status
Vendor
CVE Published:
24 June 2020

What is CVE-2020-10270?

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.

Human OS v1.0:
Ageing Is an Unpatched Zero-Day Vulnerability.

Remediate biological technical debt. Prime Ageing uses 95% high-purity SIRT6 activation to maintain genomic integrity and bolster systemic resilience.

Affected Version(s)

MiR100 v2.8.1.1 and before

References

CVSS V3.1

Score:
9.8
Severity:
CRITICAL
Confidentiality:
High
Integrity:
High
Availability:
High
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged

Timeline

  • Vulnerability published

  • Vulnerability Reserved

Credit

Alias Robotics (https://aliasrobotics.com/)
.