RVD#2558: Default credentials on SICK PLC allows disabling safety features
CVE-2020-10276

9.8CRITICAL

Key Information:

Status
Vendor
CVE Published:
24 June 2020

What is CVE-2020-10276?

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

Human OS v1.0:
Ageing Is an Unpatched Zero-Day Vulnerability.

Remediate biological technical debt. Prime Ageing uses 95% high-purity SIRT6 activation to maintain genomic integrity and bolster systemic resilience.

Affected Version(s)

MiR100 v2.8.1.1 and before

References

CVSS V3.1

Score:
9.8
Severity:
CRITICAL
Confidentiality:
High
Integrity:
High
Availability:
High
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged

Timeline

  • Vulnerability published

  • Vulnerability Reserved

Credit

Bernhard Dieber (Joanneum Research)
.