Code Execution Vulnerability in PLC Simulator on EcoStruxure Control Expert by Schneider Electric
CVE-2020-28213
8.8HIGH
Summary
A vulnerability in the PLC Simulator of EcoStruxure Control Expert allows for unauthorized command execution when specially crafted requests are sent over the Modbus protocol. This flaw arises from a lack of integrity checks during code downloads, potentially enabling attackers to manipulate the operational logic of the device.
Affected Version(s)
PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all ) PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)
References
CVSS V3.1
Score:
8.8
Severity:
HIGH
Confidentiality:
High
Integrity:
High
Availability:
High
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
Low
User Interaction:
None
Scope:
Unchanged