Cisco IoT Field Network Director Unauthenticated REST API Vulnerability

Patch this weekFull system takeover over the network, no login needed.
9.8CRITICAL

Key Information:

Vendor

Cisco

CVE ID
CVE ID:
CVE-2020-3531
Vendor
CVE Published:
18 November 2020

Timeline

Exploit known 1355 days after it was published

  • ๐Ÿ‘พ

    Exploit known to exist

  • Vulnerability published

  • Vulnerability Reserved

Badges

๐Ÿ‘พ Exploit Exists

How risky is it?

  • Yes: Works over the network, no login needed
  • Partly: Exploitation or a working exploit reported
  • No: Not on CISA's exploited list
  • No: No ransomware use seen

Our verdict

Patch this week

Exploitation is likely. Prioritise the fix.

What to do

1Check the vendor's fix

No fixed version is recorded yet. The vendor advisory is the authoritative source for patches.

Read the vendor advisory โ†—
2Can't patch yet? Reduce exposure

It can be reached over the network, so limit who can reach Cisco Iot Field Network Director (iot-fnd). Block it from the internet, allow only trusted hosts or a VPN, and turn off the affected feature if you don't use it, until you can update.

3Look for signs of compromise

Exploitation has been reported, so check logs on exposed Cisco Iot Field Network Director (iot-fnd) systems for unusual requests or new processes from before you patched.

4Why it's rated "Patch this week"
  • Exploitation or a working exploit has been reported.
  • It can be exploited remotely without credentials.
  • Its CVSS severity is critical (9.8).

What is CVE-2020-3531?

A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to access the back-end database of an affected system. The vulnerability exists because the affected software does not properly authenticate REST API calls. An attacker could exploit this vulnerability by obtaining a cross-site request forgery (CSRF) token and then using the token with REST API requests. A successful exploit could allow the attacker to access the back-end database of the affected device and read, alter, or drop information.

Affected Version(s)

Cisco IoT Field Network Director (IoT-FND)

References

DoS Vulnerability in Cisco Secure Firewall

CVE-2026-76418
CiscoCisco Secure Firewall ...๐Ÿ˜„๐Ÿ‘พ8.6HIGH

Remote Code Execution Vulnerability in Cisco Expressway Series

CVE-2026-76466
CiscoCisco Telepresence Vid...๐Ÿ˜„๐Ÿ‘พ9.8CRITICAL

Arbitrary File Write in Cisco Secure Email Gateway

CVE-2026-76519
CiscoCisco Secure Email๐Ÿ˜„๐Ÿ‘พ9.8CRITICAL
View more Cisco vulnerabilities...

Facts on this page come from the sources listed above; the writeup is AI-assisted. How we rate vulnerabilities ยท Report a correction

CVSS V3.1

Score:
9.8
Severity:
CRITICAL
Confidentiality:
High
Integrity:
High
Availability:
High
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged

CVSS V3.0

Score:
9.8
Severity:
CRITICAL
Confidentiality:
High
Integrity:
High
Availability:
High
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope: