Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are susceptible to a vulnerability where the Device-status service listens by default on UDP port 10100. This service accepts unverified UDP packets and deserializes the content, posing a risk that unprivileged attackers could exploit to execute arbitrary code remotely. This issue emphasizes the need for stringent network security measures and timely updates to protect against potential exploitation.