Denial of Service Vulnerability in Diagnostic Web Interface
Key Information
- Vendor
- Gallagher
- Status
- Controller 6000 And Controller 7000
- Vendor
- CVE Published:
- 11 September 2024
Summary
Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes. This issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior.
Affected Version(s)
Controller 6000 and Controller 7000 <= 8.70
Controller 6000 and Controller 7000 <= 8.70
Controller 6000 and Controller 7000 < 9.10
CVSS V3.1
Timeline
Vulnerability published.
Vulnerability Reserved.