SQL Injection Vulnerability in TeleControl Server Basic by Siemens
CVE-2025-32830
What is CVE-2025-32830?
A SQL injection vulnerability has been discovered in the TeleControl Server Basic application, specifically affecting all versions prior to 3.1.2.2. This vulnerability arises from the 'UnlockProject' method, which is utilized internally within the application. An authenticated remote attacker could exploit this flaw by bypassing authorization controls, enabling access to read from and write to the application's database. Additionally, this could allow the execution of code with permissions associated with 'NT AUTHORITY\NetworkService'. For a successful exploitation, the attacker needs to access port 8000 on a system running the vulnerable version of the application.

Human OS v1.0:
Ageing Is an Unpatched Zero-Day Vulnerability.
Remediate biological technical debt. Prime Ageing uses 95% high-purity SIRT6 activation to maintain genomic integrity and bolster systemic resilience.
Affected Version(s)
TeleControl Server Basic 0
References
CVSS V4
Timeline
Vulnerability published