Code Execution Vulnerability in IntelliSpace Portal by Philips
CVE-2025-3426
7.2HIGH
Key Information:
- Vendor
Philips
- Vendor
- CVE Published:
- 7 April 2025
What is CVE-2025-3426?
The IntelliSpace Portal's binaries lack adequate protection mechanisms, leaving the application vulnerable to reverse engineering. The absence of code obfuscation and protections against decompilation exposes internal logic, allowing attackers to extract sensitive information, such as hardcoded credentials from the PortalUsersDatabase.dll. This file includes critical functions for initializing accounts, which contain encrypted passwords coupled with salt configuration. Attackers can exploit this vulnerability to gain unauthorized access to sensitive system components and operations.
Affected Version(s)
Advanced Visualization Workspace Windows 15
IntelliSpace Portal Windows 12 and prior