Command Injection Vulnerability in DrayTek VigorSwitch Models
CVE-2026-71925
8.6HIGH
Key Information:
- Vendor
Draytek Corporation
- Vendor
- CVE Published:
- 24 August 2026
What is CVE-2026-71925?
Multiple DrayTek VigorSwitch models are impacted by a command injection vulnerability found in the getDetail function. This flaw arises from inadequate filtering of the username and password fields prior to command execution. A remote attacker, possessing valid administrative credentials for the device's web management interface, can exploit this vulnerability by supplying specially crafted input, allowing them to execute arbitrary commands with root privileges, which poses a significant security risk to network integrity.
Affected Version(s)
VigorSwitch FX2120 0 < 3.9.10
VigorSwitch G1280 0 < 2.9.10
VigorSwitch G1282 0 < 2.9.10
References
CVSS V4
Score:
8.6
Severity:
HIGH
Confidentiality:
High
Integrity:
High
Availability:
High
Attack Vector:
Network
Attack Complexity:
Low
Attack Required:
None
Privileges Required:
Undefined
User Interaction:
None
Timeline
Vulnerability published
Vulnerability Reserved
Credit
Jincheng Wang (@winmt)
Le Yu (Nanjing University of Posts and Telecommunications)
Xiapu Luo (The Hong Kong Polytechnic University)