Brute Force Authentication Vulnerability in Siemens HMI Panels
CVE-2020-15786
9.8CRITICAL
Key Information:
- Vendor
- Siemens
- Status
- Vendor
- CVE Published:
- 9 September 2020
Summary
A vulnerability exists in various models of Siemens SIMATIC HMI Panels, wherein these devices fail to adequately restrict excessive authentication attempts. This weakness permits a remote attacker to perform brute-force attacks, potentially allowing them to guess user passwords and gain unauthorized access to the Sm@rt Server. Implementing strong password policies and enhancing account lockout mechanisms are critical measures to mitigate this risk.
Affected Version(s)
SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) All versions < V16
SIMATIC HMI Comfort Panels (incl. SIPLUS variants) All versions <= V16
SIMATIC HMI Mobile Panels All versions <= V16
References
CVSS V3.1
Score:
9.8
Severity:
CRITICAL
Confidentiality:
High
Integrity:
High
Availability:
High
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged
Timeline
Vulnerability published
Vulnerability Reserved