Denial-of-Service Vulnerability in Siemens SIMATIC PLCs and Controllers

Check todayDenial of service over the network, no login needed.
7.5HIGH

Key Information:

Timeline

  • Vulnerability published

  • Vulnerability Reserved

How risky is it?

  • Yes: Works over the network, no login needed
  • No: No public exploit yet
  • No: Not on CISA's exploited list
  • No: No ransomware use seen

Our verdict

Check today

Find out if you're affected. If you are, patch.

What to do

1Check the vendor's fix

No fixed version is recorded yet. The vendor advisory is the authoritative source for patches.

Read the vendor advisory β†—
2Can't patch yet? Reduce exposure

It can be reached over the network, so limit who can reach Simatic Drive Controller Family. Block it from the internet, allow only trusted hosts or a VPN, and turn off the affected feature if you don't use it, until you can update.

3Why it's rated "Check today"
  • It can be exploited remotely without credentials.
  • Its CVSS severity is high (7.5).

What is CVE-2021-37205?

A vulnerability has been detected in various Siemens SIMATIC products, allowing unauthenticated attackers to trigger a denial-of-service condition. By sending specially crafted packets over port 102/tcp, an attacker can impede the normal operations of affected devices, requiring a restart to restore functionality. This affects multiple versions of the SIMATIC Drive Controller, S7-1200, S7-1500 series CPUs, and other related products. Ensuring up-to-date software and implementing security measures is crucial to mitigate risks.

Affected Version(s)

SIMATIC Drive Controller family All versions >= V2.9.2 < V2.9.4

SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) All versions >= V21.9 < V21.9.4

SIMATIC S7-1200 CPU family (incl. SIPLUS variants) All versions >= V4.5.0 < V4.5.2

References

Arbitrary Code Execution Vulnerability in Siemens Software Center

CVE-2026-110936
SiemensSiemens Software CenterπŸ‘Ύ8.4HIGH

Unauthorized Access in SIMATIC IoT2050 Devices

CVE-2026-58115
SiemensSimatic Iot2050 Advanc...πŸ˜„πŸ‘Ύ10CRITICAL

Femap Vulnerability: Out-of-Bounds Write in Catia MODEL File Parsing

CVE-2024-27907
SiemensSimcenter Femap7.8HIGH
View more Siemens vulnerabilities...

Facts on this page come from the sources listed above; the writeup is AI-assisted. How we rate vulnerabilities Β· Report a correction

CVSS V3.1

Score:
7.5
Severity:
HIGH
Confidentiality:
None
Integrity:
None
Availability:
None
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged
.