Denial of Service Vulnerability in Siemens Products

Check todayDenial of service over the network, no login needed.
7.5HIGH

Key Information:

Timeline

  • Vulnerability published

  • Vulnerability Reserved

How risky is it?

  • Yes: Works over the network, no login needed
  • No: No public exploit yet
  • No: Not on CISA's exploited list
  • No: No ransomware use seen

Our verdict

Check today

Find out if you're affected. If you are, patch.

What to do

1Update to a fixed version
SIMATIC Drive Controller CPU 1504D TF below 0 is vulnerable
SIMATIC Drive Controller CPU 1507D TF below 0 is vulnerable
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) below 0 is vulnerable
SIMATIC S7-1500 CPU 1510SP F-1 PN below 0 is vulnerable
SIMATIC S7-1500 CPU 1510SP F-1 PN below 0 is vulnerable
SIMATIC S7-1500 CPU 1510SP F-1 PN below 0 is vulnerable
Install SIMATIC Drive Controller CPU 1504D TF 0 or later
Install SIMATIC Drive Controller CPU 1507D TF 0 or later
Install SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) 0 or later
Install SIMATIC S7-1500 CPU 1510SP F-1 PN 0 or later
Read the vendor advisory โ†—
2Can't patch yet? Reduce exposure

It can be reached over the network, so limit who can reach SIMATIC Drive Controller CPU 1504D TF. Block it from the internet, allow only trusted hosts or a VPN, and turn off the affected feature if you don't use it, until you can update.

3Why it's rated "Check today"
  • It can be exploited remotely without credentials.
  • Its CVSS severity is high (7.5).

What is CVE-2023-46156?

Certain Siemens devices are vulnerable due to improper handling of specially crafted packets sent to TCP port 102. This loophole allows attackers to induce a denial of service condition, causing normal operations to cease. To restore functionality, a device restart is necessary.

References

Arbitrary Code Execution Vulnerability in Siemens Software Center

CVE-2026-110936
SiemensSiemens Software Center๐Ÿ‘พ8.4HIGH

Unauthorized Access in SIMATIC IoT2050 Devices

CVE-2026-58115
SiemensSimatic Iot2050 Advanc...๐Ÿ˜„๐Ÿ‘พ10CRITICAL

Femap Vulnerability: Out-of-Bounds Write in Catia MODEL File Parsing

CVE-2024-27907
SiemensSimcenter Femap7.8HIGH
View more Siemens vulnerabilities...

Facts on this page come from the sources listed above; the writeup is AI-assisted. How we rate vulnerabilities ยท Report a correction

CVSS V3.1

Score:
7.5
Severity:
HIGH
Confidentiality:
None
Integrity:
None
Availability:
None
Attack Vector:
Network
Attack Complexity:
Low
Privileges Required:
None
User Interaction:
None
Scope:
Unchanged
.