Session Management Vulnerability in Mendix Runtime Software

5.3MEDIUM

Key Information:

Vendor

Siemens

CVE ID
CVE ID:
CVE-2026-135278
Vendor
CVE Published:
27 November 2026
Fixed in
Fixed in:
0

Timeline

  • Vulnerability published

  • Vulnerability Reserved

How risky is it?

  • Partly: Works over the network, but needs a login
  • No: No public exploit yet
  • No: Not on CISA's exploited list
  • No: No ransomware use seen

Our verdict

Monitor

Low risk for most. Patch in your normal cycle.

What to do

1Update to a fixed version
Mendix Runtime V10 below 0 is vulnerable
Mendix Runtime V11 below 0 is vulnerable
Mendix Runtime V11.12 below 0 is vulnerable
Mendix Runtime V11.6 below 0 is vulnerable
Mendix Runtime V9 below 0 is vulnerable
Install Mendix Runtime V10 0 or later
Install Mendix Runtime V11 0 or later
Install Mendix Runtime V11.12 0 or later
Install Mendix Runtime V11.6 0 or later
Read the vendor advisory β†—
2Can't patch yet? Reduce exposure

It can be reached over the network, so limit who can reach Mendix Runtime V10. Block it from the internet, allow only trusted hosts or a VPN, and turn off the affected feature if you don't use it, until you can update.

3Why it's rated "Monitor"
  • Its CVSS severity is medium (5.3).

What is CVE-2026-135278?

A vulnerability exists in Mendix Runtime versions that fails to terminate active sessions when a user account is marked as inactive. Although the system verifies account status during sign-in, it neglects to enforce this check on subsequent requests from an already active session. This oversight enables an authenticated user whose account has been deactivated to continue accessing resources, potentially allowing them to read and modify data based on their previous permissions. Proper session management is crucial to ensure that inactive users do not maintain access to sensitive information.

References

Arbitrary Code Execution Vulnerability in Siemens Software Center

CVE-2026-110936
SiemensSiemens Software CenterπŸ‘Ύ8.4HIGH

Unauthorized Access in SIMATIC IoT2050 Devices

CVE-2026-58115
SiemensSimatic Iot2050 Advanc...πŸ˜„πŸ‘Ύ10CRITICAL

Femap Vulnerability: Out-of-Bounds Write in Catia MODEL File Parsing

CVE-2024-27907
SiemensSimcenter Femap7.8HIGH
View more Siemens vulnerabilities...

Facts on this page come from the sources listed above; the writeup is AI-assisted. How we rate vulnerabilities Β· Report a correction

CVSS V4

Score:
5.3
Severity:
MEDIUM
Confidentiality:
Low
Integrity:
Low
Availability:
None
Attack Vector:
Network
Attack Complexity:
Low
Attack Required:
None
Privileges Required:
Undefined
User Interaction:
None
.